Preparation |
Clinical Standards for Procedures and Interventions. |
|
|
Assessment |
Assess airway type (ETT or tracheostomy) and placement. |
|
|
Maintains head of bed at greater than position 35 degrees. |
|
|
Assesses skin and mucosal integrity around the airway and securement device; confirms proper tube fixation. |
|
|
Implementation |
Performs oral suctioning and oral care prior to cuff adjustment or measurement. |
|
|
Connects the cuff manometer to the pilot balloon using sterile or clean technique per policy; measures resting cuff pressure. |
|
|
Adjusts cuff volume in small increments to achieve a target cuff pressure of 20 to 30 cm H2O using minimal occluding volume or minimal leak technique per institutional policy. |
|
|
Confirms adequate seal and absence of audible leak during inspiratory phase while avoiding excessive pressure; reassesses auscultation and ventilator alarms. |
|
|
Performs Airway Suctioning (Inline Closed System) as indicated to clear secretions after cuff pressure assessment. |
|
|
Monitoring and Modifications |
Rechecks cuff pressure after patient repositioning |
|
|
Monitors for signs of underinflation (audible leak). |
|
|
Post-Intervention |
Documents cuff pressure value |
|
|
Post-Intervention Management Steps. |
|
|